地球物理学进展  2014, Vol. 29 Issue (3): 1399-1405   PDF    
工业输电线对瞬变电磁二次场的影响及干扰的消除
李风明, 刘鸿福 , 张新军, 余传涛    
太原理工大学矿业工程学院, 太原 030024
摘要:为了研究工业输电线对瞬变电磁探测效果产生的影响,建立了工业输电线模型并结合均匀半空间模型,研究了瞬变电磁二次磁场的变化率和输电线在竖直方向上磁场变化率之间的定量关系,确定了发射框半径、信噪比与距工业输电线水平距离的关系.研究表明:工业输电线的干扰在地面上是呈正弦变化的,其幅值的大小与电流强度、输电线高度和距工业输电线的水平距离有关.并据此提出了消除工业输电线干扰的方法,研究结果对在工业输电线附近进行瞬变电磁工作具有指导意义.
关键词瞬变电磁     磁场变化率     工业输电线     干扰范围     干扰的消除    
The influence of industrial transmission lines on transient electromagnetic’s second magnetic field and the elimination of interference
LI Feng-ming, LIU Hong-fu , ZHANG Xin-jun, YU Chuan-tao    
Taiyuan University of Technology, Institute of Mining Engineering, Taiyuan 030024, China
Abstract: Aiming at the impact of industrial power lines on transient electromagnetic survey effect, this thesis makes an analysis on the quantitative relationship between the changing rate of transient electromagnetic's second magnetic field and that of the power lines's magnetic field in the vertical direction to confirm the relationship among transmitting loop semidiameter, signal-to-noise ratio, horizontal distance from the industrial power lines through the established industrial power line model and uniform half-space model. Research shows that: industrial power lines interference tends to be a sinusoidal variation on the ground, whose amplitude is related to the intensity of electric current, the height of industrial power lines and horizontal distance between lines and the measuring wireframe. Naturally, the research comes to a method of eliminating the interference, which offers some tips to the transient electromagnetic detection in the neighborhood of industrial power lines.
Key words: transient electromagnetic     the changing rate of magnetic field     industrial power lines     the range of interference     the elimination of interference    
 0 引 言

瞬变电磁法(Transient electromagnetic method 简称TEM法)是一种利用不接地回线向地下发送脉冲式一次电磁场,用接收线圈观测该脉冲电磁场感应的地下涡流产生的二次电磁场(牛之琏,2007)的空间和时间分布,从而解决有关地质问题的时间域电磁方法.由于TEM的许多显著优点,使得TEM法在近几十年得到了迅速的发展(薛国强,等,2004;2008; 2011a. 2011b2013; 李永兴等,2010;陈曙东等,2012;陈晓东等,2012;丁艳飞等,2012;李貅等,2012; 孟庆鑫和潘和平,2012;邱稚鹏等,2013;张爽等,2014),然而TEM的使用会受到许多干扰的影响.

本文针对上述问题并结合实际情况,应用中心回线法并基于均匀半空间(李貅,2002)的模型进行了初步的模拟和计算,并给出了在假定情况下工业输电线对瞬变电磁探测结果的影响及其影响因子.如果对影响因子有足够深的认识,那么可以在生产过程中慎重的选择发射和接收参数,以最大程度降低工业输电线对探测结果的影响,从而提高工作效率和探测精度.

1 工业输电线干扰和TEM二次场的计算1.1 均匀半空间模型的建立和中心回线法的求解

假设均匀半空间介质的电阻率为ρ,磁导率为μ,介电常数为ε.中心回线发射线框Tx为一水平放置在地面上圆形线框,线框的半径为a,接收线框Rx位于圆线框圆心,线圈中通一阶跃电流(薛国强,2004)

为了方便求解,以发射线圈的中心为坐标原点建立柱坐标系,z轴方向向下,r方向由圆心指向外(如图 1),在忽略位移电流的情况下,则标量赫兹位F满足亥姆霍兹方程(谢处方,2008):

式中,k2=-iωμσ,在频率域中解得的Hz(ω)为(李貅,2002)

由于实际测量时,通常是测量接收线圈中的感应电动势ε(t),所以只需求出二次磁场的变化率 H(t)t .再由傅里叶反变换(刘国兴,2005)得二次磁场变化率为

式中,(概率积分函数).
图 1 均匀半空间与柱坐标系的建立Fig. 1 Establishment between half-space model and cylindrical coordinates
1.2 工业输电线模型及其产生的电磁场

相对通常线框的大小,工业输电线可看作是无限长通电长直导线,假定工业输电线为单回路三相电(西安电力学校,1981),三相电距地面的高均为h,线间距为l,距输电线水平距离为d的P点的磁感应强度 B 为三相电产生的磁场强度的矢量和(如图 2),则三相电各相的电流为

其中Im为电流的振幅,ω为频率,且ω=100 πrad/s.
图 2 工业输电线模型Fig. 2 Model of industrial transmission line

由毕奥-萨伐尔定律(谢处方,2008)可得:

联立(4)~(7)式可得U相电在P点竖直方向上的磁场为

由(8)式得U相电在P点竖直方向上的磁场变化率为

同理可得V相和W相电在P点竖直方向上的磁场变化率为

联立(9)~(11)式得三相电在P点竖直方向上产生的总磁感应强度的变化率为

1.3 工业输电线对瞬变电磁二次场的影响1.3.1 工业输电线干扰的计算

为了能具体的说明工业输电线对瞬变电磁二次场的影响,模型将取如下表 1表 2中的参数.

表 1 工业输电线模型参数(以220 kV工业线为例) Tab.1 Model parameter of industrial transmission line (set 220 kV industrial power lines as an example)

表 2 均匀半空间模型及中心回线的参数 Tab.2Parameter of uniform half-space model and center loop

为了能直观看到工业输电线对地面上每一点的影响,由(12)式绘制出工业输电线产生的与d,t的曲线关系图如图 3.

图 3 工业输电线产生的 与d,t的关系曲线图Fig. 3 Graph showing relationship among d,t and generated by industrial transmission line

经计算工业输电线产生的干扰幅值(在无特别说明的情况下,本文所述的干扰均指工业输电线在竖直方向上的磁场变化率并不是简单随着水平距离d的增大而减小,而是随着d的增大其幅值出现四个极值,两个极大值和两个极小值. 1.3.2 TEM二次场的计算

根据瞬变电磁的理论,大地中电流密度最大处的深度与时间的关系(牛之琏,2007)为

假如要探测地下200 m左右的地电特性,根据(13)式可以粗略算出需要的观测时间(在理想阶跃关断条件下的观测时间).

根据表 2的参数,由(3)式绘制出的不同发射框半径条件下的瞬变电磁二次磁场变化率与时间的关系曲线见图 4,从图中可看出,在相同发射电流条件下,半径为200 m线框的二次场变化率前期数据较大,但由于衰减较快,后期数据又变得较小;半径为300 m的线框相对于半径为200 m的线框其二次场变化率整体衰减较慢,数据较平缓,且后期二次场变化率值已高于半径为200 m的线框;同样,半径为400 m线框的二次场变化率更平缓,后期二次场变化率值已高于半径为300 m的线框,即后期大线框二次场变化率值较大.

图 4 二次磁场变化率与时间的关系Fig. 4 Relationship of the changing rate of second magnetic field and time
2 影响效果分析

2.1 工业输电线产生干扰的计算

由(12)式计算得出的工业输电线产生的干扰见表 3,从表中可得出干扰幅值随水平距离d的变化规律:在d=0.7 m时干扰幅值出现一极小值9.896×10-5 T/s,在d=2.5 m时干扰幅值出现一极大值;在d=20.25 m时干扰幅值为一极小值;在d=35.25 m时干扰幅值又为一极大值,然后又随着d的增大干扰幅值又逐渐变小(见图 5).但是无论d为何值,工业输电线在每一点产生的干扰均呈正弦曲线变化(因为(12)式在任一点总能表示成某一三角函数Acos(ωt+φ),其中A和φ为某一常数).

表 3 工业输电线附近干扰值 Tab.3Interference value in the neighborhood of industrial transmission line

图 5 工业输电线干扰振幅与水平距离的关系Fig. 5 The relationship between the amplitude and horizontal distance of industrial power lines interference

由(3)式计算得出的二次磁场变化率值见表 4.

表 4 在某一发射框半径下,观测时间对应的二次场变化率的大小 Table 4 The size of the changing rate of second magnetic field correspongding with observing time under a certain transmitting loop semidiameter

表 3数据可以看出输电线边缘(比如表 3d=2.5 m 时)干扰是最大的,它会使得小框深部信号(比如表 4a=200 m,t大于等于6×10-5 s时)的信噪比小于1 1,而使得大框信号(比如表 4a=300 m时)全部失真,这样的干扰会使得反演结果出现柱状的低阻或者高阻的假异常,并以山西娄烦某220 kV高压线下的试验为例来说明此问题. 综合比较图 4中的三条曲线和表 4中的数据可以看出,在发射电流相同和保证最后几道信噪比的同时,小线框的前期数据整体信噪比较高.

表 5 发射框半径、信噪比与距工业输电线水平距离的关系 Table 5 Relationships among transmitting loop semidiameter,signal-to-noise ratio and horizontal distance from the industrial power lines

由公式(3)、(12)和表 3、4,如果取最低信噪比为3 1或4 1,则可得出相应的距工业电线最小水平距离.

2.2 试验过程与分析

本次试验区范围内只有一条220 kV高压线,距城市村庄较远,试验当天天气晴朗可排除人文及天电影响,采用的仪器为美国Zonge公司生产的GDP-32多功能电法仪,采用固定回线的测量方式,试验的工作参数为:发射框半径分别选用a等于200 m和300 m,发射电流为10 A,接收线圈采用HZ垂直分量接收探头,等效面积为10000 m2,试验选定同一条测线,测点数为10个,点距为10 m,且测线的方向垂直于工业输电线方向,试验成果见图 6(图中横坐标x表示距工业输电线的水平距离).

图 6(a)发射框半径为200 m的视电阻率剖面图;(b)发射框半径为300 m的视电阻率剖面图.Fig. 6(a)Profile map of apparent resistivity with 200 meters semidiameter emission frame;(b)Profile map of apparent resistivity with 300 meters semidiameter emission frame.

分析图 6,在a图标高为+1098 m~+990 m(即浅部信息)时,整个视电阻率剖面图曲线平缓光滑,地层分层明显,且又与当地的地层电阻率基本吻合,看不出有明显的工业输电线干扰;但是当标高范围为+990 m~+900 m,水平距离为10 m~50 m左右时,图中明显出现了范围比较大的高阻异常区,其电阻率值是周围电阻率的2倍,且明显高于当地已知地层的电阻率,由此断定该“异常区”受到了高压线的影响,使其出现了假异常,随着水平距离x的增大,干扰又逐渐消失,到x为60 m左右时基本趋于正常.

图 6b x为10 m~55 m,标高为+1090 m~+900 m的范围内,基本上整个视电阻率剖面图呈现出高阻异常,异常区整体呈柱状,其电阻率值明显高于周围电阻率且与当地的地层电阻率不吻合,由此本文断定该“异常区”受到了工业输电线的干扰,并非真正的异常,随着水平距离x的增大,干扰又逐渐消失,到x为55 m左右时基本上也趋于正常.

综合图 6,在工业输电线附近工作时,如果发射电流及其它条件都相同,高压线可能会使小框深部的勘探信息失真而使大框的深部及浅部信息全部失真,从而出现因受干扰出现的假异常,但是随着距高压线水平距离的增大,干扰又慢慢消失,基本上在x大于60 m左右时以满足勘探的信噪比.所以在野外工作时尽量使用大电流适合的发射框,测线的布置尽量避开或者垂直高压线,已使工业输电线的干扰降到最低,提高信噪比.

本次试验区的选则与本文假定的模型相似,试验的结果基本上与本文的结论相符,验证了本文结论正确性. 2.3 干扰的处理

根据已建立的工业输电线模型可得出结论:由于工业输电线产生的干扰在每一点都呈正弦曲线变化的且居有稳定的频率,据此提出了在工业输电线附近工作时消除干扰的方法:

1 )一次场供电之前,测量工业输电线在竖直方向上的磁场变化率,拟合为时间-磁场变化率正弦曲线.

2)一次场供电以后,测量工业输电线影响下的二次场的磁场变化率,拟合出时间-磁场变化率曲线.

3 )根据第一步拟合出的时间-工业电磁场变化率正弦曲线,预测在二次场测量期间的时间-工业输电线磁场变化率正弦曲线,并将其反向.

4)将第二步拟合出的时间-二次场磁场变化率曲线和和第三步拟合出的反向的时间-工业输电线磁场变化率曲线叠加到一起,然后再拟合出新的时间-二次场磁场变化率曲线,并输出.

通过以上四步,只要工业输电线具有稳定的功率或者功率相差不大,那么在理论上就可以消除工业输电线对二次场产生的干扰,并以图 6b的干扰为例,对1~5号测点的数据按照本方法的思想进行了处理,使靠近工业输电线的物理测点的电阻率到得了还原,处理前后对比图见图 7.

图 7 干扰处理前后对比图(a)干扰处理前;(a)干扰处理前. Fig. 7 Comparative graph before and after the treatment of interference(a)Before the treatment of interference;(b)After the treatment of interference.

3 结 论

3.1    工业输电线的干扰在地面上的干扰是呈正弦变化的,其幅值的大小与电流强度、电线高度和距工业电线的距离有关.

3.2    瞬变电磁二次场的变化率与发射电流成正比,而与发射线框(本文只讨论圆形框)的关系较复杂:小框的前期数据较大,但由于其衰减较快,后期数据反而变小,即后期大框数据较大;所以在发射条件允许的情况下,为提高信噪比应选择较大的发射电流,而发射框的选择应根据实际勘探深度及地质条件来决定,既要考虑前期数据大小,又得顾虑后期的数据的信噪比,从而提高数据的整体信噪比.

3.3    除在特高压工业输电线外,一般在距高压线60~70 m左右时就已经满足其信噪比要求,如果在测量时再增加叠加次数,可能在更近的距离上就已经满足了信噪比.

3.4    对干扰的处理,本文选择了娄烦县某高压线附近的一条剖面,经过处理取得了明显的效果,使采集到的带有干扰的信号得到了还原,同时也说明了本文所提出的消燥方法的可行性.

致 谢    感谢刘鸿福老师,张新军老师和王闻贵师兄等在本文撰写期间给予的帮助与指导,同时也感谢审稿专家所提的宝贵意见及编辑部的热心帮助.

参考文献
[1] Chen X D, Lin J, Zhang S, 2012. Effect of transmitter current waveform on TEM response[J].Chinese J. Geophys.(in Chinese),55(2):709-715.
[2] Cheng J W, 2007.Researches on The Application of Transient Electromagnetic Method in coal Minging[D].TaiYuan University of Technology[Master Degree thesis].
[3] Chen X D, Zhao Y, Zhang J, et al. 2012.The applications of HTc SQUID magnetometer to TEM. Chinese J.Geophys. (in Chinese),55(2): 702-708,doi: 10.6038/j.issn.0001-5733.2012.02.034.
[4] Danielsen J E, Auken E, Ding Y F, et al.2012.A rapid algorithm for calculating time domain transient electromagnetic responses of a large fixed rectangular loop on the half space. Chinese J.Geophys. (in Chinese),(6): 2087-2096,doi: 10.6038/j.issn.0001-5733.2012.06.030.
[5] Jorgensen F, et al, 2003. The application of the transient electromagnetic method in hydrogeophysical surveys. Journal of Applied Geophysics,53(4):181-198.
[6] Feng S W, Liu W Z, Yang X D.2010. The Effectiveness of Applying the Transient Electromagnetic Method in High Interference Area to The Exploration of Mined-out Area[J].Geophysical and Geochemical Exploration,34(2):195-197.
[7] Haber E, Oldenburg D W, Shekhtman R. 2007. Invertsion of time domain three-dimensional electromagnetic data. Geophysical Journal International, 171(2):550-564.
[8] Hou Y W. 2012. The detection on the using of transient electromagnetic method seach for deep water source in Inner Mongolia [J]. Progress In Geophysics,27(6):2698-2702.
[9] Jiang B Y. 1998. A Practical Near-zone Magnetic Source Transient Electromagnetic Exploration(in Chinese). Beijing: Geological Publishing House.
[10] Li J H, Liu S C, Li F, et al. 2008. Electromagnetic Field Transmitted by Rectangular Loop in Large Fixed TEM [J].Computing Techniques for Geophysics and Geochemical Exploration,30(2):154-157.
[11] Li J H,Zhu Z Q, Ru G Y, et al. 2013. Study on three-dimensional forward of transient electromagnetic method excited by loop source [J].Progress In Geophysics,28(2):754-764.
[12] Li X, Xue G Q, Liu Y A, et al. 2012.A research on TEM imaging method based on synthetic-aperture technology. Chinese J.Geophys. (in Chinese),55(1): 333-340,doi: 10.6038/j.issn.0001-5733.2012.01.034.
[13] Li Y X, Qiang J K, Tang J T, et al. 2010.A research on 1-D forward and inverse airborne transient electromagnetic method. Chinese J.Geophys. (in Chinese),53(3): 751-759,doi: 10.3969/j.issn.0001-5733.2010.03.031.
[14] Li X. 2002. The Theory and Application of transient Electromagnetic Sounding.Xi'an:Shanxi Science Technology Press.
[15] Liu G X. 2005. Principles and Methods of Electrical Prospecting(in Chinese).Beijing: Geological Publishing House.
[16] Niu Z L. 2007. Tine-domain Electromagnetic Principle(in Chinese).Changsha: Central South University Press.
[17] Meng Q X, Pan H P. 2012.Numerical simulation analysis of surface-hole TEM responses. Chinese J.Geophys. (in Chinese),55(3): 1046-1053,doi: 10.6038/j.issn.0001-5733.2012.03.035.
[18] Raiche A P. 1984. The effect of ramp function turn-off on the TEM response of layered earth.Ex ploration Geophysics, 15(1):37-41.
[19] Qiu Z P, Li Z H, Li D Z, et al. 2013.Non-orthogonal-Grid-based three dimensional modeling of transient electromagnetic field with topography. Chinese Journal Geophysics,56(12): 4245-4255,doi: 10.6038/cjg20131227.
[20] Shi X X, Yan S, Chen M S. 2005. Study on Screening of Conductive Bed in Transient Electromagnetic Prospecting. Journal of China Coal Society (in Chinese),30(2):160-163.
[21] Shi X X, Yan S, Fu J M, et al. 2009. Improvement for interpretation of central loop transient electromagneti method. Chinese[J].Chinese Journal of Geophysics,52(7):1931-1936.
[22] Spies B.R and Parber P.D. 1984. Limitations of large-loop transient electromagnetic surveys in conductive terrains.Geophysics.V49.
[23] Wang H J. 2008. Time domain transient electromagnetism all time apparent resistivity translation algorithm[J].Chinese Journal of Geophysics, 2008,51(6):1936-1941.
[24] Wang H J, Luo Y Z. 2003. Algorithm of A 2. 5 Dimensional Finite Element Method for Transient Electromagmatic With a Central Loop. [J].Chinese Journal of Geophysics,46(6):855-861.
[25] Xi'an Electric Power University. 1981. Electric Power[M].Beingjing: Electric Power Indrostry Press.
[26] Xiao Y, Qiu W Z, Yang X M. 2012. Evaluation of Measuring Yime and Signal—noise Ratio in Central Loop TEM Design [J].Coal Geology and Exploration,40(5):86-88.
[27] Xie C F, Rao K J. 2008. Electromagnetic Field and Electromagnetic Wave[M].Beijing:High Education Press.
[28] Xue G Q, Yan S, Zhou N N. 2011. Theoretical study on the errors caused by dipole hypothesis of large-loop TEM response. Chinese J.Geophys. (in Chinese), 54(9): 2389-2396,doi: 10.3969/j.issn.0001-5733.2011.09.022.
[29] Xue G Q, Li X, Qi Z P, et al. 2011.Study of sharpen the wave-form of TEM pseudo-seismic. Chinese J.Geophys. (in Chinese), 54(5): 1384-1390,doi: 10.3969/j.issn.0001-5733.2011.05.028.
[30] Xue G Q, Li X, Qi Z P, et al. 2011. Study of sharpen the wave-form of TEM pseudo-seismic.Chinese J. Geophys. (in Chinese), 54(5): 1384-1390,doi: 10.3969/j.issn.0001-5733.2011.05.028.
[31] Xue G Q, Chen W Y, Zhou N N, et al. 2013. Short-offset TEM technique with a grounded wire source for deep sounding[J].Chinese Journal of Geophysics, 56(1):255-260.
[32] Xue G Q, Li L, Di Q Y. 2008. Research progress in TEM Forward modeling and inversion calculation[J]. Progress In Geophysics, 23(4):1165-1172.
[33] Xue G Q, Song J P, Yan S, et al. 2004. Feasibility analysis of transient electromagnetic method for detecting underground cave[J].Journal of China University of Petroleum: Edition of Natural Science, 28(5):135-138.
[34] Zhang S, Liu Z X, Chen S D. 2014. Calibration study on the damping characteristics of TEM sensor. Chinese Journal Geophysics,57(2): 662-670,doi: 10.6038/cjg20140229.
[35] Zhang S Y, Pan Y L. 2004. Applied Geophysics Principle(in Chinese). Beijing:China university of Geosciences Press.
[36] 陈曙东,林君,张爽.2012.发射电流波形对瞬变电磁响应的影响[J]. 地球物理学报,52(2):709-715. doi: 10.6038/j.issn.0001-5733.2012.02.034.
[37] 陈晓东, 赵毅, 张杰, 等. 2012.高温超导磁强计在瞬变电磁法中的应用研究. 地球物理学报, 55(2): 702-708,doi: 10.6038/j.issn.0001-5733.2012.02.034.
[38] 成剑文. 2007.瞬变电磁法在煤矿应用中的研究[D].太原: 太原理工大学[硕士论文].
[39] 丁艳飞, 白登海, 许诚. 2012.均匀半空间表面大定源瞬变电磁响应的快速算法. 地球物理学报, (6): 2087-2096,doi: 10.6038/j.issn.0001-5733.2012.06.030.
[40] 封绍武,刘文增,杨晓东.2010.强干扰区瞬变电磁法勘查采空区效果[J]. 物探与化探,34(2):195-197.
[41] 侯彦威.2012.内蒙古地区深部水源瞬变电磁法探测[J].地球物理学进展,27(6):2698-2702.
[42] 蒋邦远.1998.实用近区磁源瞬变电磁法勘探[M]. 北京:地质出版社.
[43] 李建慧,刘树才,李富,等.2008.大定源瞬变电磁法矩形发射回线激发的电磁场[J].物探化探计算技术,30(2):154-157.
[44] 李建慧,朱自强,鲁光银,等.2013.回线源瞬变电磁法的三维正演研究[J].地球物理学进展,28(2):754-764.
[45] 李貅.2002.瞬变电磁测深的理论与应用[M].西安:陕西科学技术出版社.
[46] 李永兴,强建科,汤井田. 2010.航空瞬变电磁法一维正反演研究. 地球物理学报, 53(3): 751-759,doi: 10.3969/j.issn.0001-5733.2010.03.031.
[47] 李貅, 薛国强, 刘银爱, 等.2012.瞬变电磁合成孔径成像方法研究. 地球物理学报, 55(1): 333-340,doi: 10.6038/j.issn.0001-5733.2012.01.034.
[48] 孟庆鑫, 潘和平. 2012.地-井瞬变电磁响应特征数值模拟分析. 地球物理学报 ,55(3): 1046-1053,doi: 10.6038/j.issn.0001-5733.2012.03.035.
[49] 刘国兴.2005.电法勘探原理与方法[M]. 北京:地质出版社.
[50] 牛之琏.2007.时间域电磁法原理[M].长沙:中南大学出版社.
[51] 邱稚鹏, 李展辉, 李墩柱, 等. 2013.基于非正交网格的带地形三维瞬变电磁场模拟. 地球物理学报, 56(12): 4245-4255,doi: 10.6038/cjg20131227.
[52] 石显新,闫述,陈明生. 2005. 瞬变电磁勘探中的低阻层屏蔽问题[J].煤炭学报,30(2):160-163.
[53] 石显新,闰述,傅君眉,等.2009.瞬变电磁法中心回线装置资料解释力法的改进[J].地球物理学报,52(7): 1931-1936.
[54] 王华军.2008.时间域瞬变电磁法全区视电阻率的平移算法[J].地球物理学报,51(6):1936-1941.
[55] 王华军,罗延钟.2003.中心回线瞬变电磁法2.5维有限单元算法[J].地球物理学报,46(6):855-861.
[56] 肖勇,丘卫忠,杨小明.2012. 中心回线TEM勘探设计中观测时间和信噪比估算[J].煤田地质与勘探,40(5):86-88.
[57] 谢处方, 饶克谨. 2008. 电磁场与电磁波[M]. 北京: 高等教育出版社.
[58] 薛国强,陈卫营,周楠楠,等.2013.地源瞬变电磁短偏移深部探测技术[J].地球物理学报,56(1):255-260.
[59] 薛国强,李琳,底青云.2008.瞬变电磁法正反演问题研究进展[J].地球物理学进展,23(4):1165-1172.
[60] 薛国强,宋建平,闫述,等.2004. 瞬变电磁探测地下洞体的可行性分析[J]. 石油大学学报(自然科学版),28(5):135-138.
[61] 薛国强, 闫述, 周楠楠. 2011.偶极子假设引起的大回线源瞬变电磁响应偏差分析. 地球物理学报, 54(9): 2389-2396,doi: 10.3969/j.issn.0001-5733.2011.09.022.
[62] 薛国强, 李貅, 戚志鹏, 等. 2011.瞬变电磁拟地震子波宽度压缩研究. 地球物理学报, 54(5): 1384-1390,doi: 10.3969/j.issn.0001-5733.2011.05.028.
[63] 张爽, 刘紫秀, 陈曙东.2014.瞬变电磁传感器阻尼特性的标定研究. 地球物理学报,57(2): 662-670,doi: 10.6038/cjg20140229.
[64] 张胜业,潘玉玲. 2004.应用地球物理学原理[M].北京:中国地质大学出版社.